Element |
TAL* |
Comments |
|
Element
|
TAL
|
|
|
Preconditioning |
Pot/Wave |
SAC305 |
SN100E |
Copper (Cu) |
0.750 |
0.300 |
Above 1.00% may cause bridging and sluggish solder flow. |
|
Tin (Sn) |
BAL |
BAL |
|
|
Bismuth (Bi) |
0.250 |
0.250 |
If levels exceed 0.2% contamination source should be investigated. |
|
Lead (Pb) |
0.10 |
0.10 |
RoHS Directive 2002/95/EC Maximum. |
|
Zinc (Zn) |
0.008 |
0.005 |
May cause higher levels of bridging, icicling and surface oxidation. |
|
Copper (Cu) |
|
0.30-1.00 |
Above 1.00% may cause bridging and sluggish solder flow.
|
|
Iron (Fe) |
0.020 |
0.020 |
Indicator of pot erosion and may cause joint gritty formation and the formation of FeSn2. |
|
Bismuth (Bi) |
0.20 |
0.20 |
If levels exceed 0.2% contamination source should be investigated. |
|
Silver (Ag) |
0.750 |
0.100 |
Solderability can be affected. |
|
Zinc (Zn) |
0.003 |
0.003 |
May cause higher levels of bridging, icicling and surface oxidation. |
|
Antimony (Sb) |
0.500 |
0.500 |
Enhances thermal fatique and joint strength. |
|
Iron (Fe) |
0.02 |
0.02 |
Indicator of pot erosion and may cause joint gritty formation and the formation of FeSn2. |
|
Nickel (Ni) |
0.025 |
0.010 |
Solder drossing, sluggish. |
|
Silver (Ag) |
2.8-3.5 |
0.20 |
Solderability can be affected. |
|
Cadmium
(Cd)
|
0.010 |
0.005 |
RoHS Directive 2002/95/EC Maximum. |
|
Antimony (Sb) |
0.20 |
0.20 |
Lead free alloys can tolerate up to 1.0%. |
|
Aluminum (Al) |
0.008 |
0.006 |
May cause higher levels of bridging, icicling and surface oxidation. |
|
Nickel (Ni) |
0.05 |
<0.01* 0.05 |
* Solder drossing, sluggish. Slow wetting speed and reduce hole fill.
|
|
Gold (Au) |
0.500 |
0.200 |
At levels above 0.1% joint strength may be compromised. Sluggish solder. |
|
Cadmium (Cd) |
0.003 |
0.003 |
RoHS Directive 2002/95/EC Maximum. |
|
Arsenic (As) |
0.030 |
0.030 |
Levels greater than 0.03% can cause de-wetting. |
|
Aluminum (Al) |
0.002 |
0.002 |
May cause higher levels of bridging, icicling and surface oxidation. |
|
*Per J-STD-001 |
|
Gold (Au) |
0.10 |
0.10 |
At levels above 0.1% joint strength may be compromised. |
|
|
|
Arsenic (As) |
0.03 |
0.03 |
Levels greater than 0.03% can cause de-wetting. |
|
|
|
Cobalt (Co) |
N/A |
<0.01 |
Solderability can be affected and long term joint reliability at risk. |
|
|
|
Germanium (Ge) |
N/A |
<0.005* |
* Solder drossing, sluggish. |
|
|
|
* Applies to a popular Sn/Cu/Ni/Ge alloy only. |
|
This data is based on information that the mfg. believed to be reliable and offered in good faith. Qualitek International, Inc. makes no warranties expressed or implied as to its accuracy and assumes no responsibilities and liabilities arising out of its use by others as conditions and methods of use of the products are beyond the control of Qualitek International, Inc. The user must determine the suitability of the product before using it on a commercial basis. The warranties extend only t the conformity of the product to the physical descriptions. In no event will Qualitek International, Inc. be responsible for special, incidental and consequential damages whether the claim is in contract, negligence r otherwise. Qualitek specifically disclaims an liability for consequential or incidental damages of any kind, including lost profits. |
|